Sign In | Join Free | My futurenowinc.com
China KOMEG Technology Ind Co., Limited logo
KOMEG Technology Ind Co., Limited
KOMEG Technology Ind Co., Limited Top Brand Climatic Test Chamber Since 1990
Active Member

12 Years

Home > Thermal Shock Test Chamber >

Water Cooled Programmable Thermal Shock Test Chamber Two Zone / Three Zone

KOMEG Technology Ind Co., Limited
Contact Now

Water Cooled Programmable Thermal Shock Test Chamber Two Zone / Three Zone

Brand Name : KOMEG

Model Number : KTS-A Series

Certification : CE

Place of Origin : guangdong

MOQ : 1 piece Thermal Shock test Chamber

Price : USD2000-USD20000/ piece

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 1000 pieces a year

Delivery Time : 25 to 35 days

Packaging Details : Strong Plywood Case, Meet International Standard

products name : Thermal Shock Test Chamber

Low Temp. chamber : -55ºC~-10ºC

Test. chamber : -40 °C~ +150°C

Refrigeration system : Water Cooled

Exterior material : Stainless steel plate

Power : AC 380±10%50Hz

Controller : LCD Touch panel

Contact Now

Two-zone or three-zone Programmable Thermal Shock Test Chamber

Thermal Shock Chambers Overview:

KOMEG thermal shock chambers meet the demands of today's environmental stress screening with proven performance in installations around the world. Our direct transfer method between hot and cold is an economical method to achieve rapid part temperature change for ESS or thermal shock.

Thermal shock test chamber is requisite testing equipment in metal, plastic, rubber, electronics and other industries. It is used for testing the material structure or composite material’s tolerance degree when exposed instantly in extremely high temperature and extremely low temperature environment continuously, so that whose chemical or physical damage due to thermal expansion and contraction can be detected in shortest time.

3-Zone Thermal Shock Chambers Working Principle:

The three-zone type thermal shock test chamber. Sample is placed in the test chamber, more extreme temperature than test temperature can be set in high-temperature chamber and low-temperature chamber. During low temperature test, cold chamber door open, and low-temperature chamber working together with test chamber. When converted into high-temperature test, cold chamber door closed, hot chamber door are opened, and test chamber working together with high-temperature chamber.

Conversion of mechanical action (transferring from high temperature to low temperature or low temperature to high temperature) can be completed in less than 1 second, and the temperature can be quickly stabilized.

During the whole test, test sample is no need to be moved, and without any human intervention.

Below are differences between3-zone and 2-zone thermal shock chamber:

3-zonethermal shock chamber:

three chamber in total: test space, high temp. chamber and low temp. chamber;

Advantage: slight limitation for test sample’s weight, the test sample keep still, this can reduce the impact to samples by moving it, can be used for on-load testing.

Compared with 2-zone type, relatively low failure rate, low cost.

Disadvantage: long conversion time

2-zonethermal shock chamber:

only two chambers: high temp. Chamber and low temp.chamber

Advantage: short conversion time, smaller space needed

Disadvantage: test sample moving. test samples’ size is limited by the basket size

Standards Met and Implemented:


GB/T2423.1.2
GB10592-89
GJB150

Specifications:

3 Zone Thermal Shock Test Chamber
Specifications Note:1. We reserve the right to change specifications without prior notice
2. Customized sizes and configurations available
Model KTS-A Series
72A 100A 150A 200A 252A 300A 480A
Interior size W(mm) 450 500 600 670 700 800 800
H(mm) 400 450 500 600 600 600 800
D(mm) 400 450 500 500 600 650 750
Exterior size W(mm) 1490 1540 1640 1720 1750 1850 1850
H(mm) 1790 1840 1890 2000 2000 2000 2200
D(mm) 1600 1700 1830 1850 1930 1980 2500
Test weight(KG) 5 10 12 15 18 20 20
Low Temp. chamber -55ºC~-10ºC
Pre-heat time +20ºC~-55ºC ,Within 60 min
Test. chamber -40ºC~+150ºC
High Temp. chamber +60ºC~+200ºC
Pre-heat time +60ºC~+200ºC ,Within 20 min
Recovery time High-Temp Exposure 30 min
Low-Temp Exposure 30 min
Recovery time within 5 min
Safety device No fuse breaker, over pressureover heat and over current protection for compressor,over temperature protection, over load protection for blower, dry heat protection
Standard accessory Cable port(portΦ50mm)*1, shelves*2
Interior material Stainless steel plate(SUS 304)
Exterior material Baked painting steel or stainless steel(SUS304)
Insulation material Rigid polyurethane Foam+glass fiber wool
Refrigeration system Water Cooled
Semi-hermetic compressor, cascade refrigeration system, CFC free refrigerant(HFC-507 and HFC-23)
Controller Panel:7-inch LCD Touch panel,Chinese or English display selectable
Operation model:Program or fix point running
Memory capacity:120programs,1200steps,all repeat 999cycles,part repeat 99 cycles.
Accuracy:Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit
Input:Temp.:pt-100 Humidity:pt-100 or ~5V DCV
Ambient Temp. +5ºC~+35ºC
Power AC 380±10%50Hz ,3 phase 4 wires +Ground Wires

3 Zone Thermal Shock Test Chamber
Specifications Note:1. We reserve the right to change specifications without prior notice 2. Customized sizes and configurations available
Model KTS-B Series
72B 100B 150B 200B 252B 300B 480B
Interior size W(mm) 450 500 600 670 700 800 800
H(mm) 400 450 500 600 600 600 800
D(mm) 400 450 500 500 600 650 750
Exterior size W(mm) 1490 1540 1640 1720 1750 1850 1850
H(mm) 1790 1840 1890 2000 2000 2000 2200
D(mm) 1600 1700 1830 1850 1930 1980 2500
Test weight(KG) 5 10 12 15 18 20 20
Low Temp. chamber -70ºC~-10ºC
Pre-heat time +20ºC~-70ºC ,Within 60 min
Test. chamber -55ºC~+150ºC
High Temp. chamber +60ºC~+200ºC
Pre-heat time +60ºC~+200ºC ,Within 20 min
Recovery time High-Temp Exposure 30 min
Low-Temp Exposure 30 min
Recovery time within 5 min
Safety device No fuse breaker, over pressureover heat and over current protection for compressor,over temperature protection, over load protection for blower, dry heat protection
Standard accessory Cable port(portΦ50mm)*1, shelves*2
Interior material Stainless steel plate(SUS 304)
Exterior material Baked painting steel or stainless steel(SUS304)
Insulation material Rigid polyurethane Foam+glass fiber wool
Refrigeration system Water Cooled
Semi-hermetic compressor, cascade refrigeration system, CFC free refrigerant(HFC-507 and HFC-23)
Controller Panel:7-inch LCD Touch panel,Chinese or English display selectable
Operation model:Program or fix point running
Memory capacity:120programs,1200steps,all repeat 999cycles,part repeat 99 cycles.
Accuracy:Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit
Input:Temp.:pt-100 Humidity:pt-100 or ~5V DCV
Ambient Temp. +5ºC~+35ºC
Power AC 380±10%50Hz ,3 phase 4 wires +Ground Wires

3 Zone Thermal Shock Test Chamber
Specifications Note:1. We reserve the right to change specifications without prior notice
2. Customized sizes and configurations available
Model KTS-D Series
72D 100D 150D 200D 252D 300D
Interior size W(mm) 450 500 600 670 700 800
H(mm) 400 450 500 600 600 600
D(mm) 400 450 500 500 600 650
Exterior size W(mm) 1490 1540 1640 1720 1750 1850
H(mm) 1790 1840 1890 2000 2000 2000
D(mm) 1600 1700 1830 1850 1930 1980
Test weight(KG) 5 10 12 15 18 20
Low Temp. chamber -80ºC~-10ºC
Pre-heat time +20ºC~-80ºC ,Within 60 mins
Test. chamber -65ºC~+150ºC
High Temp. chamber +60ºC~+200ºC
Pre-heat time +60ºC~+200ºC ,Within 20 min
Recovery time High-Temp Exposure 30 min
Low-Temp Exposure 30 min
Recovery time within 5 min
Safety device No fuse breaker, over pressureover heat and over current protection for compressor,over temperature protection, over load protection for blower, dry heat protection
Standard accessory Cable port(portΦ50mm)*1, shelves*2
Interior material Stainless steel plate(SUS 304)
Exterior material Baked painting steel or stainless steel(SUS304)
Insulation material Rigid polyurethane Foam+glass fiber wool
Refrigeration system Water Cooled
Semi-hermetic compressor, cascade refrigeration system, CFC free refrigerant(HFC-507 and HFC-23)
Controller Panel:7-inch LCD Touch panel,Chinese or English display selectable
Operation model:Program or fix point running
Memory capacity:120programs,1200steps,all repeat 999cycles,part repeat 99 cycles.
Accuracy:Temp.:0.1% of F.S±1 digit Humidity:0.1% of F.S±1 digit
Input:Temp.:pt-100 Humidity:pt-100 or ~5V DCV
Ambient Temp. +5ºC~+35ºC
Power AC 380±10%50Hz ,3 phase 4 wires +Ground Wires

Main features of Thermal test chamber:
1. Programmable Controller with RS232C, 7 LCD touch panel control
2. Stainess steel Interior, galvanized steel sheet exterior
3.2PCS stainless steel loading shelves free
4. Multipane viewing window with heater
5. 50mm diameter feed-through port
6. Floor stand with castors.

Packaging:

Climatic thermal shock test chamber are covered with air bubble film before put them into the strong plywoodcase, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, crash-proof, etc.

Water Cooled Programmable Thermal Shock Test Chamber Two Zone / Three Zone

Water Cooled Programmable Thermal Shock Test Chamber Two Zone / Three Zone


Product Tags:

temperature shock test chamber

      

thermal shock chamber

      
Wholesale Water Cooled Programmable Thermal Shock Test Chamber Two Zone / Three Zone from china suppliers

Water Cooled Programmable Thermal Shock Test Chamber Two Zone / Three Zone Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: KOMEG Technology Ind Co., Limited
*Subject:
*Message: